AT-406
MASTER
1
SUB
3
70
Handset Intercom
AT-206
AT-306 x 3
Master calls all the subs simultaneously, while the sub rings the master only.
Communication network
Power source 6V DC, 150mA
Power supply PS-0602D, PS-0602C or Batteries gAAh (SUM-3)
x 4 pcs
Communication Press CALL button to ring all subs. Pick up any
phone. Sub rings master only. Common talk.
Wiring 2 parallel wires. non-polarized
Distance 2-station set 700m(0.65mma)
1000m(0.8mma)
AT-206 to subs 1~3 400m(0.65mma)
600m(0.8mma)
Specifications (AT-406)
AT-206
AT-306
80
210
51
83.5
Unit dimensions